Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 60(3)2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38541101

RESUMEN

Background and Objectives: Unstable atherosclerotic plaque in the arteries is one of the main risk factors for cerebral ischemia. Duplex ultrasound is a frequently used diagnostic method, but it has some limitations for microvascularization and neovascularization evaluation. The aim of this review was to evaluate the role of the new multiparametric US method-contrast-enhanced ultrasound (CEUS)-in atherosclerotic plaque instability verification. Materials and Methods: Original studies, reviews, and meta-analyses were included in this article. A total of 53 studies were retrieved; 29 were included in this study. Results: Carotid artery CEUS as a part of the multiparametric ultrasound method shows promising results and provides additional characteristics of soft- and high-risk atherosclerotic plaques; it can be advised in clinical practice for patients with carotid artery soft- and high-risk plaques. However, there are some limitations, such as extensive calcinosis with important acoustic shadows in carotid atherosclerotic plaque neovascularization diagnostics by CEUS. The added value of CEUS in the characterization of atherosclerotic plaque is that it indicates regions with high neovascularization and visualizes ulcerations on plaque surfaces, suggestive of increased instability risk.


Asunto(s)
Estenosis Carotídea , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Medios de Contraste , Arterias Carótidas/diagnóstico por imagen , Ultrasonografía
2.
EJNMMI Radiopharm Chem ; 8(1): 27, 2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37823964

RESUMEN

BACKGROUND: In order to support the ongoing research across Europe to facilitate access to novel radionuclides, the PRISMAP consortium (European medical radionuclides programme) was established to offer the broadest catalog of non-conventional radionuclides for medical and translational research. The aim of this article is to introduce readers with current status of novel radionuclides in Europe. MAIN BODY: A consortium questionnaire was disseminated through the PRISMAP consortium and user community, professional associations and preclinical/clinical end users in Europe and the current status of clinical end-users in nuclear medicine were identified. A total of 40 preclinical/clinical users institutions took part in the survey. Clinical end users currently use the following radionuclides in their studies: 177Lu, 68 Ga, 111In, 90Y, other alpha emitters, 225Ac, 64Cu and Terbium isotopes. Radionuclides that would be of interest for users within the next 2-5 years are 64Cu, Terbium radionuclide "family" and alpha emitters, such as 225Ac. CONCLUSIONS: Thanks to a questionnaire distributed by the PRISMAP consortium, the current status and needs of clinical end-users in nuclear medicine were identified.

3.
Diagnostics (Basel) ; 12(12)2022 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36553183

RESUMEN

BACKGROUND: Early diagnosis of recurrent prostate cancer is a cornerstone for further adequate therapy planning. Therefore, clinical practice and research still focuses on diagnostic tools that can detect prostate cancer in early recurrence when it is undetectable in conventional diagnostic imaging. 18F-PSMA-1007 PET/CT is a novel method to evaluate patients with biochemical recurrent PCa. The aim of this review was to evaluate the role of 18F-PSMA-1007 PET/CT in prostate cancer local recurrence, lymph node metastases and bone metastases detection. METHODS: Original studies, reviews and five meta-analyses were included in this article. A total of 70 studies were retrieved, 31 were included in the study. RESULTS: All patients described in the studies underwent 18F-PSMA-1007 PET/CT. The administered 18F-PSMA-1007 individual dose ranged from 159 ± 31 MBq to 363.93 ± 69.40 MBq. Results showed that 18F-PSMA-1007 PET/CT demonstrates a good detection rate in recurrent prostate cancer. CONCLUSIONS: 18F-PSMA-1007 PET/CT appears to achieve reliable performance in detecting recurrent prostate cancer. The high detection rate of 18F-PSMA-1007 PET/CT in recurrent prostate cancer was confirmed, especially in local recurrence and small lymph nodes with non-specific characteristics on conventional diagnostic imaging methods. However, several authors emphasize some limitations for this tracer-for example, non-specific uptake in bone lesions that can mimic bone metastases.

4.
Cancers (Basel) ; 13(21)2021 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-34771632

RESUMEN

Ultrasound has been established as a baseline imaging technique for thyroid nodules. The main advantage of adding CEUS is the ability to assess the sequence and intensity of vascular perfusion and hemodynamics in the thyroid nodule, thus providing real-time characterization of nodule features, considered a valuable new approach in the determination of benign vs. malignant nodules. Original studies, reviews and six meta-analyses were included in this article. A total of 624 studies were retrieved, and 107 were included in the study. As recognized for thyroid nodule malignancy risk stratification by US, for acceptable accuracy in malignancy a combination of several CEUS parameters should be applied: hypo-enhancement, heterogeneous, peripheral irregular enhancement in combination with internal enhancement patterns, and slow wash-in and wash-out curve lower than in normal thyroid tissue. In contrast, homogeneous, intense enhancement with smooth rim enhancement and "fast-in and slow-out" are indicative of the benignity of the thyroid nodule. Even though overlapping features require standardization, with further research, CEUS may achieve reliable performance in detecting or excluding thyroid cancer. It can also play an operative role in guiding ablation procedures of benign and malignant thyroid nodules and metastatic lymph nodes, and providing accurate follow-up imaging to assess treatment efficacy.

5.
Am J Nucl Med Mol Imaging ; 11(5): 395-405, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34754610

RESUMEN

The aim of this study was to compare the diagnostic tools-18F-PSMA-1007 positron emission tomography (PET/CT), magnetic resonance imaging (MRI) and bone scintigraphy for the evaluation of local recurrence, regional lymph nodes and bone metastases of recurrent prostate cancer (PCa). 28 PCa patients after radical prostatectomy and/or radiation therapy and with biochemical relapse were enrolled in this study. The evaluation of local recurrence and regional lymph node metastases was based on results of PET/CT and MRI. Local recurrent disease in 28 patients was detected by PET/CT in 36% (10/28) and by MRI in 32% (9/28) with sensitivity, specificity, accuracy of 90.9%, 100%, 96.4% and 81.8%, 100%, 92.9%, respectively (kappa 0.92, P<0.001). Nodal involvement was confirmed by PET/CT and MRI in 46% (13/28) and 25% (7/28) with sensitivity, specificity and accuracy for PET/CT 92.3%, 93.3%, 92.9% and for MRI-53.8%, 100%, 78.6%, respectively (kappa 0.57, P<0.001). The evaluation of skeletal metastases was based on PET/CT and bone scintigraphy. Bone metastases were seen on PET/CT and bone scintigraphy in 21% (6/28) and 20% (5/25) with sensitivity, specificity and accuracy of 100%; 91.7%; 92.9% and 50.0%; 85.7%; 80.0%, respectively (kappa 0.41, P<0.01). In conclusion, our comparative study demonstrates advantages of 18F-PSMA-1007 PET/CT compared to MRI and scintigraphy for the evaluation of recurrent prostate cancer. Both methods, 18F-PSMA-1007 PET/CT and MRI, detect local recurrence with high accuracy and excellent agreement, which may be attributed to the low urinary background clearance of 18F-PSMA-1007.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...